Go to homepage
Applications
Cameras
Interfaces
Converter
About us
Contact
Show all Applications
Aerospace
Broadcast & AV Production
Deep Sea
Inspection
Medical
Surveillance
Traffic Control
Unmanned aerial vehicles (UAV)
Show all Cameras
Camera Selector
HD Modul Cameras
HD Block Cameras
4K Block Cameras
Security Cameras
Hanhwa Wisenet P
Hanhwa Wisenet X
Hanhwa Wisenet T
Hanhwa Wisenet Q
Hanhwa Wisenet L
Hanhwa Wisenet HD+
Show all Interfaces
Interface Selector
Serial digital interface (SDI)
HDMI
Optical Fibre
Analog SD and HD
USB
Accessory
Show all Converter
Converter Selector
3G/HD-SDI TO HDMI
HDMI TO SDI
HDMI to 3G/HD-SDI with Board Connector
Show all About us
Press Releases
New UHD HDMI to 6G-SDI converter - NA4K2022
New 6G-SDI video interface for block cameras - TL4K1171
New Full-HD TVI / AHD video interface for block cameras
New CVBS analog video interface for block cameras - TL9801
New HDMI to SDI converter with a board-to-board connector
3G-SDI & analog YPbPr combination interface - TL7055
New 3G-SDI HD-SDI Interface Board - TL8651
New HDMI Interface Board - TL8652
Linecard
AIVION
Tamron
Sony
Hanhwa Techwin
eVision Systems
Blog
Wishlist
My account
Login
or sign up
Overview Your profile Addresses Payment methods Orders
Shopping cart €0.00*
Show all categories USB Back
  • Show USB
  1. Home
  2. Interfaces
  3. USB
Selector
Analog
SDI
HDMI
USB
Optical

USB 3.0 Interfaces

Filter
–
TL6032 | USB 3.0 Horizontal Micro B Interface
TL6032 | USB 3.0 Horizontal Micro B Interface
The TL6032 interface is a HDTV USB 3.0 compliant video streaming capture solution from AIVION. As no analog to digital conversion is done on these modules, excellent output image quality is guaranteed. Features: USB 3.0 Video Output Up to 1080p30 uncompressed HDTV video data, 4:2:2 YUV format 1920x1080p @ 25Hz, 29.97Hz, 30 Hz 1280x720p @ 50Hz, 59.94Hz, 60Hz, 25Hz, 29.97Hz, 30Hz The module receives digital video signals at the input and sends UVC (USB Video Class) compliant data packets containing digital video payload to a connected host computer Small Form Factor Small form factor 45mm x 40mm USB Operates always as Super Speed USB3.0 device (Host or OTG operation modes are not supported) Host computer must run a UVC capable operating system Parallel up- and downstream of camera control and status data is possible (USB CDC) Power Full USB bus powered camera solution possible depending on camera Power supply voltage for camera is generated onboard Allows an external power supply Compliance RoHS compliant (2002/05/EG and 2011/65/EU) UL/UR compliant Temperature Range Ambient temperature (min/max): -5°C/+60°C = 23°F/140°F Operating humidity range 20% to 80% Download TL6032 V2.0.0 Datasheet TL6032 Block Diagram Power Input: 5V DC from USB3 port Characteristics: Power consumption (FCB-EV75xx + TL6035) 5.6W Power consumption (FCB-SE600 + TL6035) 3.5W (cam motors inactive) Power consumption TL6035: 2.7W/540mA@5V DC (max.) Operating and Storage Conditions: Operating Conditions: Ambient temperature (min/max): -5°C/+60°C = 23°F/140°F - Humidity: 20%-80% Storage Conditions: Temperature (min/max): -20°C/+60°C = -4°F/ 140°F - Humidity: 20%-80% TL6032 PCB Connectors J6 USB3 microB connector Horizontal J2 LVDS Video In 30wire microcoax connector for 4K Block Cameras. Use 30wire micro coaxial cable supplied with cable kit. J7 External Power Supply Pin Signal 1 Input voltage 5V to 7V DC 2 Input voltage 5V to 7V DC 3 System reset, pull to GND for reset 4 GND (0V) 5 GND (0V) J9 RS232 UART Connector Pin Signal 1 to 7 do not connect 8 GND 9 RXD (host to camera) 10 TXD (camera to host) TL6032 PCB Outline Camera Power Camera supply voltage is generated on TL6032 by a boost converter circuit. This circuit provides 9.55V DC (+/-3%) to the camera. NOTE: USB3.0 is specified for 4.5W maximum output power per USB3.0 port on a computer. However, many main boards used in desktop computer systems are able to provide more USB3 output power. In case of notebook and laptop computers, IPCs and SBCs, it has to be checked case by case if USB3 output power is sufficient or not. This is in the sole responsibility of the user of TL6032. TL6032 EXTERNAL POWER OPTION: TL6032 allows to use an external power supply in case USB3 power of the used computer is not sufficient. As described on page 3 of this document, external power can be input on J7. Using a voltage of 6V DC is recommended. In case an external power supply is used, this voltage is used on TL6032 for the camera supply boost converter only. All other electronic devices on TL6032 are always powered from USB3 port. No adjustments on TL6032 are required for using external power. When powering up such a configuration, external power must be supplied before or coincident with USB3 power. Host (PC) - Device Communication TL6032 operates always as USB device which sends UVC compliant video data to a host PC. The host also communicates with the TL6032 via a serial communication channel (USB UART). Connecting the TL6032 to the Host PC Operating System Support TL6032 can be used with operating systems which fully support USB UVC type data and communication. Currently supported Microsoft Windows operating systems: Windows 7 (32 and 64bit) Windows 8.1 (32 and 64bit) Windows 10 (64bit, version 1511) Driver Requirements Full UVC compliant driver is required. Such drivers are supplied with Microsoft Windows 7 and 8 . Manual driver installation is not necessary. For the USB UART feature, the class driver is used. Aivion provides suitable driver assignment files. Win 10 does not require such a driver assignment file. Video Application on Host PC Video display and recording can be done with standard application programs like VLC player, Mplayer or similar. VLC and Mplayer are open source based applications and can be free downloaded. If users want to design their own applications software, they are free to do so. All software programming tasks are OS based and have to be built upon UVC drivers. For further information please refer to Microsoft Windows API information. Controlling TL6032 from the Host PC via USB UART TL6032 supports the USB UART functionality. FCB cameras connected to TL6032 can be controlled via a virtual COM port. Any host software which uses COM ports can be used. The USB UART channel is transparent for any protocol. Communication speed is 9600bit/ s or 38400bit/s maximum. Other COM port settings are (8N1). TL6032 | Production Kit Partnumber Content TL6032 USB 3.0 Board TLCK-K30-200 30 pin KEL USL type micro coaxial cable, connector on both sides, length 20cm, Type 1:n TL6032-EXT | Evaluation Extension Partnumber Content EK-PA1100-USB Power supply and control interface board PS-TE10A05 5 V AC to DC external power supply with interchangeable blade kit for USA, Europe, United Kingdom and Australian. TL-EVK-USB-SA USB to serial adapter TL-EVK-BRA Bracket and screws TL-EVK-USB3-A-MICROB USB 3.0 Cable with a USB 3.0-A male and a USB 3.0 micro-B male connector

Price on request

Details
TL6035 | USB 3.0, Vertical Micro B Connector
TL6035 | USB 3.0, Vertical Micro B Connector
The TL6035 USB 3.0 interface board from AIVION is a tiny and easy to use HDTV USB3.0 video capture interface for the block cameras. The module receives digital video signals and sends UVC (USB Videl Class) compliant data packets to a connected host computer. Our compact TL6035 module enables the design of small camera systems that need only a single connection between camera and PC. Video stream, control data and power will be connected by a USB 3.0 cable. For camera blocks that need more than 900 mA during startup a Y-cable is required. Features: USB 3.0 Video Output Up to 1080p30 uncompressed HDTV video data, 4:2:2 YUV format 1920x1080p @ 25Hz, 29.97Hz, 30 Hz 1280x720p @ 50Hz, 59.94Hz, 60Hz, 25Hz, 29.97Hz, 30Hz The module receives digital video signals at the input and sends UVC (USB Video Class) compliant data packets containing digital video payload to a connected host computer Small Form Factor Small form factor 45mm x 40mm USB Operates always as Super Speed USB3.0 device (Host or OTG operation modes are not supported) Host computer must run a UVC capable operating system Parallel up- and downstream of camera control and status data is possible (USB CDC) Power Full USB bus powered camera solution possible depending on camera Power supply voltage for camera is generated onboard Allows an external power supply Compliance RoHS compliant (2002/05/EG and 2011/65/EU) UL/UR compliant Temperature Range Ambient temperature (min/max): -5°C/+60°C = 23°F/140°F Operating humidity range 20% to 80% Datasheet TL6035 V2.0.0 Application Note TL6035 TL6035 Block Diagram Power Input: 5V DC from USB3 port Characteristics: Power consumption (FCB-EV75xx + TL6035) 5.6W Power consumption (FCB-SE600 + TL6035) 3.5W (cam motors inactive) Power consumption TL6035: 2.7W/540mA@5V DC (max.) Operating and Storage Conditions: Operating Conditions: Ambient temperature (min/max): -5°C/+60°C = 23°F/140°F - Humidity: 20%-80% Storage Conditions: Temperature (min/max): -20°C/+60°C = -4°F/ 140°F - Humidity: 20%-80% TL6035 PCB Connectors J6 USB3 microB connector Vertical J2 LVDS Video In 30wire microcoax connector for 4K Block Cameras. Use 30wire micro coaxial cable supplied with cable kit. J7 External Power Supply Pin Signal 1 Input voltage 5V to 7V DC 2 Input voltage 5V to 7V DC 3 System reset, pull to GND for reset 4 GND (0V) 5 GND (0V) J9 RS232 UART Connector Pin Signal 1 to 7 do not connect 8 GND 9 RXD (host to camera) 10 TXD (camera to host) TL6035 PCB Outline Camera Power Camera supply voltage is generated on TL6035 by a boost converter circuit. This circuit provides 9.55V DC (+/-3%) to the camera. NOTE: USB3.0 is specified for 4.5W maximum output power per USB3.0 port on a computer. However, many main boards used in desktop computer systems are able to provide more USB3 output power. In case of notebook and laptop computers, IPCs and SBCs, it has to be checked case by case if USB3 output power is sufficient or not. This is in the sole responsibility of the user of TL6035. TL6035 EXTERNAL POWER OPTION: TL6035 allows to use an external power supply in case USB3 power of the used computer is not sufficient. As described on page 3 of this document, external power can be input on J7. Using a voltage of 6V DC is recommended. In case an external power supply is used, this voltage is used on TL6035 for the camera supply boost converter only. All other electronic devices on TL6035 are always powered from USB3 port. No adjustments on TL6035 are required for using external power. When powering up such a configuration, external power must be supplied before or coincident with USB3 power. Host (PC) - Device Communication TL6035 operates always as USB device which sends UVC compliant video data to a host PC. The host also communicates with the TL6035 via a serial communication channel (USB UART). Connecting the TL6035 to the Host PC Operating System Support TL6035 can be used with operating systems which fully support USB UVC type data and communication. Currently supported Microsoft Windows operating systems: Windows 7 (32 and 64bit) Windows 8.1 (32 and 64bit) Windows 10 (64bit, version 1511) Driver Requirements Full UVC compliant driver is required. Such drivers are supplied with Microsoft Windows 7 and 8 . Manual driver installation is not necessary. For the USB UART feature, the class driver is used. Aivion provides suitable driver assignment files. Win 10 does not require such a driver assignment file. Video Application on Host PC Video display and recording can be done with standard application programs like VLC player, Mplayer or similar. VLC and Mplayer are open source based applications and can be free downloaded. If users want to design their own applications software, they are free to do so. All software programming tasks are OS based and have to be built upon UVC drivers. For further information please refer to Microsoft Windows API information. Controlling TL6035 from the Host PC via USB UART TL6035 supports the USB UART functionality. FCB cameras connected to TL6035 can be controlled via a virtual COM port. Any host software which uses COM ports can be used. The USB UART channel is transparent for any protocol. Communication speed is 9600bit/ s or 38400bit/s maximum. Other COM port settings are (8N1). TL6035 | Production Kit Partnumber Content TL6035 USB 3.0 Vertical Micro B USB Board TLCK-K30-200 30 pin KEL USL type micro coaxial cable, connector on both sides, length 20cm, Type 1:n TL6035-EXT | Evaluation Extension Partnumber Content EK-PA1100-USB Power supply and control interface board PS-TE10A05 5 V AC to DC external power supply with interchangeable blade kit for USA, Europe, United Kingdom and Australian. TL-EVK-USB-SA USB to serial adapter TL-EVK-BRA Bracket and screws TL-EVK-USB3-A-MICROB USB 3.0 Cable with a USB 3.0-A male and a USB 3.0 micro-B male connector

Price on request

Details
TL6636 | USB 3.0, Vertical Micro B Connector (Trigger)
TL6636 | USB 3.0, Vertical Micro B Connector (Trigger)
The TL6636 USB 3.0 interface board with trigger functionality from AIVION is tiny and easy to use HDTV USB3.0 video capture interface for the block cameras. The module receives digital video signals and sends UVC (USB Videl Class) compliant data packets to a connected host computer. Our compact TL6636 module enables the design of small camera systems that need only a single connection between the camera and PC. Video stream, control data and power will be connected by a USB 3.0 cable. For camera blocks that need more than 900 mA during startup, a Y-cable is required. Features: USB 3.0 Video Output Up to 1080p30 uncompressed HDTV video data, 4:2:2 YUV format 1920x1080p @ 25Hz, 29.97Hz, 30 Hz 1280x720p @ 50Hz, 59.94Hz, 60Hz, 25Hz, 29.97Hz, 30Hz The module receives digital video signals at the input and sends UVC (USB Video Class) compliant data packets containing digital video payload to a connected host computer Trigger Real-time external trigger input for MP2030M-GS global shutter camera block Single LVDS data format provided by Tamron camera blocks USB Operates always as Super Speed USB3.0 device (Host or OTG operation modes are not supported) Host computer must run a UVC capable operating system Parallel up- and downstream of camera control and status data is possible (USB CDC) Power Full USB bus powered camera solution possible depending on camera Power supply voltage for camera is generated onboard Allows an external power supply Compliance RoHS compliant (2002/05/EG and 2011/65/EU) UL/UR compliant Temperature Range Ambient temperature (min/max): -5°C/+60°C = 23°F/140°F Operating humidity range 20% to 80% Download TL6636 V2.0.0 Datasheet TL6636 Block Diagram Power Input: 5V DC from USB3 port Characteristics: Power consumption (MP2030M-GS + TL6636) 7.65W (cam motors inactive) Power consumption (MP2030M-GS + TL6636) 9.3W (boot cyle and cam motors active) Power consumption TL6636: 2.7W/540mA@5V DC (max.) Power consumption value conditions: Camera monitoring mode set to 1080p30 Ambient temperature +25°C/77°F Humidity 30% Operating and Storage Conditions: Operating Conditions: Ambient temperature (min/max): -5°C/+60°C = 23°F/140°F - Humidity: 20%-80% Storage Conditions: Temperature (min/max): -20°C/+60°C = -4°F/ 140°F - Humidity: 20%-80% TL6636 PCB Connectors J6 USB3 microB connector Vertical J2 LVDS Video In 30wire microcoax connector for 4K Block Cameras. Use 30wire micro coaxial cable supplied with cable kit. J7 External Power Supply Pin Signal 1 Input voltage 5V to 7V DC 2 Input voltage 5V to 7V DC 3 System reset, pull to GND for reset 4 GND (0V) 5 GND (0V) J9 RS232 UART Connector Pin Signal 1 External trigger pulse* input, 3.3V max. Active high trigger pulse duration must be 1us minimum. Trigger pulse input has a 10kohms pullup resistor 2 Trigger demo mode select input**, 3.3V max. Trigger mode select input has a 10kohms pulldown resistor 3 do not connect 4 Trigger response output 5 3.3V output (20mA max.) 6 do not connect 7 do not connect 8 GND 9 RXD (host to camera) 10 TXD (camera to host) TL6636 PCB Outline Camera Power Camera supply voltage is generated on TL6636 by a boost converter circuit. This circuit provides 9.55V DC (+/-3%) to the camera. NOTE: USB3.0 is specified for 4.5W maximum output power per USB3.0 port on a computer. However, many main boards used in desktop computer systems are able to provide more USB3.0 output power. In case of notebook and laptop computers, IPCs and SBCs, it has to be checked case by case if USB3.0 output power is sufficient or not. This is in the sole responsibility of the user of TL6636. In case the host computer provides a USB3.1 port, it is recommended to use this one instead of a USB3.0 port. TL6636 EXTERNAL POWER OPTION: TL6636 allows to use an external power supply in case USB3 power of the computer is not sufficient. As described on page 3 of this document, external power can be input on J7. Using a voltage of 6V DC is recommended. In case an external power supply is used, this voltage is used on TL6636 for the camera supply boost converter only. All other electronic devices on TL6636 are always powered from USB3 port. No adjustments on TL6636 are required for using external power. When powering up such a configuration, external power must be supplied before or coincident with USB3 power. EXTERNAL POWER USE PER CAMERA MODEL: MP2030M-GS: Recommended, should be used MP1010M-VC: Not required but can be used MP1110M-VC: Not required but can be used Host (PC) - Device Communication TL6636 operates always as USB device which sends UVC compliant video data to a host PC. The host also communicates with the TL6636 via a serial communication channel (USB UART). Connecting the TL6636 to the Host PC Operating System Support TL6636 can be used with operating systems which fully support USB UVC type data and communication. Currently supported Microsoft Windows operating systems: Windows 7 (32 and 64bit) Windows 8.1 (32 and 64bit) Windows 10 (64bit, version 1511) Driver Requirements Full UVC compliant driver is required. Such drivers are supplied with Microsoft Windows 7 and 8 . Manual driver installation is not necessary. For the USB UART feature, the class driver is used. Aivion provides suitable driver assignment files. Win 10 does not require such a driver assignment file. Video Application on Host PC Video display and recording can be done with standard application programs like VLC player, Mplayer or similar. VLC and Mplayer are open source based applications and can be free downloaded. If users want to design their own applications software, they are free to do so. All software programming tasks are OS based and have to be built upon UVC drivers. For further information please refer to Microsoft Windows API information. Controlling TL6636 from the Host PC via USB UART TL6636 supports the USB UART functionality. FCB cameras connected to TL6636 can be controlled via a virtual COM port. Any host software which uses COM ports can be used. The USB UART channel is transparent for any protocol. Communication speed is 9600bit/ s or 38400bit/s maximum. Other COM port settings are (8N1). Real-Time external Trigger Operation NOTE: EXTERNAL TRIGGER IS AVAILABLE WITH MP2030M-GS ONLY. Tamron’s MP2030M-GS global shutter block camera module allows for real- time triggered still image capture. Refer to MP2030M-GS technical manual provided by Tamron for details on real-time triggered still image capture operation. TL6636 USB3 full HD video streamer provides a trigger mode input for selecting one out of two available trigger modes. Mode 1 (default, pin2/J9 0V or open): External direct trigger Trigger pulse input on pin1/J9 is glitch filtered and driven to MP2030M-GS trigger input po Mode 2 (pin2/J9 3.3V): Automatic periodic trigger (demo mode) After selecting and activating trigger mode at MP2030M-GS by the related VISCA commands, the automatic trigger period is set to 1.5s. In this demo mode the camera takes an image every 1.5s (approx.). TL6636 | Production Kit Partnumber Content TL6636 USB 3.0 Vertical (Trigger) TLCK-B 1. TLCK-K30-200 30 pin KEL USL type micro coaxial cable, connector on both sides, length 20cm, Type 1:n 2. TLCK-FL10-150 10 pin flying leads cable for power and control(RS232/TTL), length 15cm 3. TLCK-FL05-150 5 pin flying leads cable for external power, length 15cm TL6636-EXT | Evaluation Extension Partnumber Content EK-PA1100-USB Power supply and control interface board PS-TE10A05 5 V AC to DC external power supply with interchangeable blade kit for USA, Europe, United Kingdom and Australian. TL-EVK-USB-SA USB to serial adapter PTL-EVK-BRA Bracket and screws TL-EVK-USB3-A-MICROB USB 3.0 Cable with a USB 3.0-A male and a USB 3.0 micro-B male connector

Price on request

Details
Newsletter

Just subscribe to our newsletter and you will always be among the first to be informed about new products and offers.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Privacy *
Service hotline

Support and counselling via: +49 (0)8121 - 2208-0 Mon-Fri, 9 am - 5 pm

Or via our contact form.
Legal Terms
  • Delivery and Payment
  • Imprint
  • Privacy
  • Terms and Conditions
Good reasons for eVision
  • Our best price guarantee
  • Professional advice
  • Fast shipping
  • Many payment methods
  • Best service
  • Low shipping costs
Shipping methods
Ex Works
Payment methods
PayPal
Paid in advance
Invoice
Company

eVision Systems GmH
Jahnstr. 12
85661 Forstinning/Munich
Germany

Safe shopping


SSL
About us

The eVision Systems Video Shop is the official international online shop for all AIVION products and complementary equipment for video system integrators.

Our communities
  • Facebook
  • Twitter
  • YouTube
  • LinkedIn
  • Xing
  • Website

    * All prices excl. VAT and shipping costs are ex works Forstinning/Munich. Errors and omissions excepted. Our offer is directed exclusively to commercial customers in the sense of §14 BGB.

    © 2023 eVision Systems Video - All Rights Reserved. Theme by ThemeWare®
    This website uses cookies to ensure the best experience possible. More information...
    Request sent successfully
    Request wasn't send - a error occured. Please try again.

    Request an offer

    Request an offer for the choosen products

    Product(s) in this request:
    Please enter a valid email address.
    Fields marked with * are mandatory.
    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.